Modbus-rtu (over rs-485) – Hardy HI 6600 Series Modular Sensor System User Manual

Page 62

Advertising
background image

HI 6600 Series Modular Sensor System User Guide

Page | 62

Modbus-RTU (over RS-485)

Modbus-RTU Commands and Parameters

Slave Address Parameter

The Slave Address parameter is a unique network address between 1 and 247 assigned to the HI 6600
series instrument.
On the Web page: select the communication menu and then select the Modbus RTU submenu, and left
click inside the Slave Address text field and enter the Slave Address assigned to the HI 6600 series
instrument.

On the HI 6110 optional display: select the communication menu and use the UP or DOWN button to
select the Modbus-RTU submenu, then select the Slave Address menu item. The current Slave Address
value will be displayed, press the ENTER or the RIGHT button if the Slave Address needs to be modified.

Baud Rate Parameter

No specific baud rate is specified for Modbus-RTU, the Baud Rate parameter is used to match the baud rate
set by the master device, typically 9,600 or 19,200.

On the Web page: select the communication menu and then select the Modbus RTU submenu and left
click inside the Baud Rate text field and enter the Baud Rate.