Get lmpt, Projector user commands, Format – Canon SX 50 User Manual

Page 150: Response, Description, Example, Commands supported, Environment

Advertising
background image

Projector User Commands


- 144 -

Revision History / Date

Changes

Revised by

Approved by

GET LMPT

Lamp lighting time inquiry

Format

GETLMPT
?
LMPT

Response

g:LMPT=<Lighting time (hours):Number>:<Lighting time (minutes):Number>


<Lighting time (hours):Number>:=Any 1 to 5-digit number from 0 to 65535
<Lighting time (minutes):Number>:=Any 2-digit number from 00 to 59

For details on other responses, refer to the "Error List".

Description

This command is used to inquire about the lamp lighting time.

(1) This inquiry can be made in any status provided that AC power is supplied to the projector.
(2) Range of values is 0 hour 0 minute to 65535 hours 59 minutes.

Example

> GET LMPT or ? LMPT

< g:LMPT=123:45

Lamp lighting time is 123 hours 45 minutes

* Commands are indicated by ">", and responses are indicated by "<".

Commands supported

This defines the environments that support the command (power supply state, input signal state).

SX50

01.00**

SX6

01.01**

SX60

01.01**

X600

01.01**

SX7

01.01**

X700

01.01**

SX7 Mark II

01.02**

x x x x x x O

* When a command is not supported, "e:000A INVALID_PARAMETER" is returned.

Environment

This defines the environments that support the command (power supply state, input signal state).

Power

Input

Mode

Model

OFF ON PM

D-RGB A-RGB1 A-RGB2 COMP

Video S-Video D-Video SCART None Remote Local

Remarks

SX50 -

-

- - - - - - - - - - - -

SX6, SX60,

X600

-

-

- - - - - - - - - - - -

SX7,

X700

-

-

- - - - - - - - - - - -

SX7 Mark II O

O O

O

O

O

O

O

O

O

O

O

O

O

* If a state is not supported, "INVALID_MODE" is returned with the Err response.

* When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.

Reference

Advertising