DPON

Direct power-on setting

Format

DPON=<Direct power-on setting parameter:ID>

Parameter

<Direct power-on setting parameter:ID>

ON

This sets direct power-on to ON.

OFF

This sets direct power-on to OFF.

The parameters which can be set at any given point in time can be obtained using the RANGE
command. For details, refer to the RANGE command.

Response

"i:OK" is returned if the parameter was set properly.
For details on other responses, refer to the "Error List".

Description

This command is used to set direct power-on function to ON or OFF.

(1) For models other than SX7 Mark II: It can be executed when the projector is in both the remote mode and

power-on status at the same time.
For SX7 Mark II: It can be executed whenever the projector is in the power-on status.

(2) A “busy” response is given while the zoom or focus lens is being driven.

(Refer to the ZCONTDRV command and FCONTDRV command.)

(3) This command functions in the same way as when "System setting" - "Direct power-on" are selected on the

menu.

(4) Direct power-on cannot be set to ON when "OFF" has been selected as the power management setting

(PMM=OFF).
("e:1004 POWER_MANAGEMENT_OFF" is returned.)

(5) The GET command can be used to retrieve the current direct power-on setting.

For details, refer to the GET command.

Example

Setting

> DPON=ON

Direct power-on is set to ON.

< i:OK

Reference

> GET DPON on ?DPON

The current direct power-on setting is obtained.

< g:DPON=ON

Acquisition of parameters which can be set

> RANGE DPON

< r:DPON=I,ON,OFF

"ON" or "OFF" can be set for direct power-on.

* Commands are indicated by ">", and responses are indicated by "<".

Commands supported

This defines the environments that support the command (power supply state, input signal state).

SX50

01.00**

SX6

01.01**

SX60

01.01**

X600

01.01**

SX7

01.01**

X700

01.01**

SX7 Mark II

01.02**

x O O O O O O

* When a command is not supported, "e:0002 INVALID_COMMAND" is returned.

Environment

This defines the environments that support the command (power supply state, input signal state).

Power

Input

Mode

Model

OFF ON PM

D-RGB A-RGB1 A-RGB2 COMP

Video S-Video D-Video SCART None Remote Local

Remarks

SX50 -

-

- - - - - - - - - - - -

SX6, SX60,

X600

x

O

x

O

O

O

O

O

O

O

O

O

O

x

SX7, X700

x

O

x

O

O

O

O

O

O

O

O

O

O

x

SX7 Mark II x

O

x

O

O

O

O

O

O

O

O

O

O

O

* If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response.
* When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.

Setting

Advertising