Nosig, Projector user commands, Format – Canon SX 50 User Manual

Page 81: Parameter, Response, Description, Example, Commands supported

Advertising
background image

Projector User Commands


- 75 -

Revision History / Date

Changes

Revised by

Approved by

NOSIG

Display screen when no signal setting

Format

NOSIG=<Parameters for setting display screen in no-signal mode:ID>

Parameter

<Parameters for setting display screen in no-signal mode:ID>

For models other than SX7 Mark II

BLACK Black

screen

BLUE Blue

screen

LOGO User

screen

For SX7 Mark II

BLACK Black

screen

BLUE Blue

screen

The parameters which can be set at any given point in time can be obtained using the RANGE
command. For details, refer to the RANGE command.

Response

"i:OK" is returned if the parameter was set properly.
For details on other responses, refer to the "Error List".

Description

This sets the display screen when no image signals are input.

(1) For models other than SX7 Mark II: It can be executed when the projector is in both the remote mode and

power-on status at the same time.
For SX7 Mark II: It can be executed whenever the projector is in the power-on status.

(2) A “busy” response is given while the zoom or focus lens is being driven.

(Refer to the ZCONTDRV command and FCONTDRV command.)

(3) This command has the same function as the buttons listed in the table below.

Model

Menu

SX50

[Display settings] - [User screen settings] - [Screen in no-signal mode]

SX6, SX60, X600, SX7, X700,
SX7 Mark II

[Display settings] - [User screen settings] - [Screen in no-signal mode]

(4) To select the user screen (LOGO), the user image must be registered ahead of time. (If the user image is

not registered, "e:1002 NO_LOGO_CAPTURED" is returned.) *However, this excludes SX7 Mark II.

(5) The GET command can be used to retrieve the current display screen at no signal.

For details, refer to the GET command.

Example

Setting

> NOSIG=BLUE

This sets the “Blue” screen when no signals are input.

< i:OK

Reference

> GET NOSIG or ?NOSIG

This retrieves the screen when no signals are input.

< g:NOSIG=LOGO

Acquisition of parameters which can be set

> RANGE NOSIG

< r:NOSIG=I, BLACK, BLUE, LOGO

"BLACK," "BLUE" or "LOGO" can be set for the display screen

in the no-signal mode.

* Commands are indicated by ">", and responses are indicated by "<".

Commands supported

This defines the environments that support the command (power supply state, input signal state).

SX50

01.00**

SX6

01.01**

SX60

01.01**

X600

01.01**

SX7

01.01**

X700

01.01**

SX7 Mark II

01.02**

O O O O O O O

Setting

Advertising