Projector User Commands


- 14 -

Revision History / Date

Changes

Revised by

Approved by

7. Power Management Mode


Concerning the processing for switching to the power management standby or exit mode in the remote or local
mode.

Mode

SX50

SX6/SX60/X600/SX7/X700/SX7 Mark II

Remote

The power management standby or exit
mode is not established.
(No countdown is initiated.)

The power management standby or exit mode is
established when no signals are supplied for at least 5.
The countdown is aborted by any command other than
GET/RANGE.
Control is switched to the "local mode" in the standby or
exit mode.

Local

The power management standby or exit mode is established when no signals are supplied for at
least 5 minutes.

Projecting in

progress

Lamp

cooling in

progress

Lamp off

Power Off

Lamp on

Power management activated

Processing only for commands
enabled in power management

standby mode

When the standby

mode is established

When the exit mode
is established

Events for returning from standby mode

Signal input

Pressing of a button on main unit or remote control

REMOTE command

RC/MAIN command (excluding RC/MAIN*-REP)