Assemble voltage detector, Test strike system, Jt60/jt60 all terrain operator’s manual – Ditch Witch JT60AT User Manual

Page 124

Advertising
background image

Systems and Equipment - 124

JT60/JT60 All Terrain Operator’s Manual

Electric Strike System

Assemble Voltage Detector

1.

Drive voltage stake into ground at least 6’ (2 m)
away from any part of system.

2.

Clip voltage limiter to voltage stake.

Test Strike System

If system fails any part of this test, see “Troubleshoot Strike System” on the following page. Do not drill until
test is completed successfully.

1.

Turn on drilling unit.

2.

Verify that display is connected to ESID control module.

3.

To test alarms and strobe, press the test button on the left console.

4.

Press the ESID soft key to view test results and historical data stored in the ESID module. This data
includes:

ESID bar graph

alphanumeric readout showing volts and amps

current diagnostic codes, or diagnostic codes detected during previous tests

5.

Use Electric Strike Simulator to test voltage and current sensors. See page 126.

Advertising
This manual is related to the following products: