1000 hour, Drilling unit, Jt60/jt60 all terrain operator’s manual – Ditch Witch JT60AT User Manual

Page 193

Advertising
background image

JT60/JT60 All Terrain Operator’s Manual

Service - 193

1000 Hour

1000 Hour

Drilling Unit

Change Hydraulic Fluid and Filters
(Normal Conditions)

Change hydraulic fluid and three filters every
1000 hours for normal service. Drain hydraulic
fluid, change filters (1, 2), and refill with THF at
hydraulic fluid fill. Tank capacity is 36 gal (136 L).

Location

Task

Notes

DRILLING
UNIT

Change hydraulic fluid and filters

normal conditions

Change ground drive gearbox oil

2 gearboxes, MPL

Change spindle brake oil

THF

Change fluid pump oil

SAE 30 non-detergent

Change anchor driver gearbox oil

Lube SaverLok wrench collar and sliding output shaft

EPL (gel)

Check engine drive belt

IMPORTANT:

If ambient temperature exceeds 100°F
(37°C) for 50% of time, change oil and
filter every 500 hours.

If hydraulic system must be opened for
repair, install new filter (p/n 157-486) for
first 50 hours of operation. If this filter
becomes plugged in fewer than 20 hours,
replace with clean filter. After 50 hours of
normal operation, replace with clean filter.

j40om061w.eps