Use electric strike simulator, Jt60/jt60 all terrain operator’s manual – Ditch Witch JT60AT User Manual

Page 126

Advertising
background image

Systems and Equipment - 126

JT60/JT60 All Terrain Operator’s Manual

Electric Strike System

Use Electric Strike Simulator

Use the Electric Strike Simulator (p/n 259-506) to test voltage and current sensors on ESID. If readings are
less than indicated here, replace 9V battery in simulator and retest.

Current Test

To test for current at normal levels:

1.

Thread one lead wire through current transformer.

2.

Clip ends of lead wires together to make one loop.

3.

On engine display, use soft keys to select ESID.

4.

Move simulator switch to "current" and press test button.

5.

Watch display:

ESID graph should show on display

ESID % and Current “AMPS” should show 30-50% on display

To test for current at strike levels:

1.

Put two or three loops through current transformer.

2.

Follow steps above to test.

3.

Display should show a strike detection warning and alarm and strobe should turn on.

With two loops:

Current should be 80-110%;

Strike indication might go on and off.

With three loops:

Current should be 130-160%

Strike indication should be continuous

Advertising
This manual is related to the following products: