Example configurations, Example configurations –2 – Altera POS-PHY Level 2 and 3 Compiler User Manual

Page 30

Advertising
background image

3–2

Chapter 3: Functional Description

Example Configurations

POS-PHY Level 2 and 3 Compiler User Guide

© November 2009

Altera Corporation

Preliminary

POS-PHY level 3 is a point-to-point system—transmit joins to transmit; channel 0
joins to channel 0, and so on (see

Figure 3–3

). POS-PHY level 2 is a unidirectional bus

system.

Example Configurations

Figure 3–4 on page 3–2

shows a packet-processing function, which receives packets at

one end from a POS-PHY PHY interface, processes them, and passes them on to a
POS-PHY link interface.

Figure 3–2. Example Interface

Figure 3–3. Connecting POS-PHY Level 3 MegaCore Functions

'A' Source

Interface

FIFO

'B1' Sink
Interface

FIFO

'B2' Sink
Interface

FIFO

'B3' Sink
Interface

FIFO

'B

n'' Sink

Interface

MegaCore Function

Sink

Interface

PHY Transmit

Function

Link Transmit

Function

Source

Interface

Source

Interface

PHY Receive

Function

Link Receive

Function

Sink

Interface

Figure 3–4. Example Configuration—Use of the Atlantic Interface

Level 3

Link

Interface

FIFO

FIFO

FIFO

Packet

Processing

Function

MegaCore Function 1

100 MHz

32 bit

FIFO

FIFO

FIFO

Level 3

PHY

Interface

MegaCore Function 2

100 MHz

32 bit

Atlantic

Interfaces

Atlantic

Interfaces

Advertising