5 main and extension frame power connections, 5 main and extension frame power, Connections – Cadac F-Type User Manual

Page 14

Advertising
background image

1-6

Connecting the mixer systems

F-Type

Revision F2005-2

41618

0DLQ#DQG#H[WHQVLRQ#IUDPH#SRZHU#FRQQHFWLRQV

See fig 1-4 below for schematics of the frames power connections.

1.

Using a short U-LINK cable (supplied), connect one of the outputs on the ±18V
PSU to one of the outputs on the +13V/+48V PSU in the “SYSTEM 1" power
supply rack. This operation “links” the d/c outputs on both power supply units in
the rack so that ±18V, +13V and +48V is available on all remaining output con-
nectors on either power unit.

2.

Connect the second short “U-LINK” cable (supplied) between the ±18V PSU and
the +13V/+48V PSU’s in the “SYSTEM 2" power supply rack.

3.

Connect a PSU cable between the “SYSTEM 1" rack and the “PSU SYSTEM 1"
connector on the MAIN FRAME.

4.

Connect a PSU cable between the “SYSTEM 2" rack and the “PSU SYSTEM 2"
connector on the MAIN FRAME.

5.

Connect a PSU cable between the “SYSTEM 1" rack and the “PSU SYSTEM 1"
connector on the EXTENSION FRAME 1.

6.

Connect a PSU cable between the “SYSTEM 2" rack and the “PSU SYSTEM 2"
connector on the EXTENSION FRAME 1.

7.

Repeat procedures 5. and 6. for EXTENSION FRAME 2 (a 3 frame console).

FIG 1-6. Power connections

368#6<67(0#4#+“4;9,

368#6<67(0#5#+“4;9,

368#6<67(0#4#+7;92.469, 368#6<67(0#5#+7;92.469,