Input modules

3-7

Revision F2005-2

F-Type

For full details on using the SAFE/READY/WRITE modes, see chapter

2.1 CCM

Front Panel switches and displays

and

2.1.1 Safe/Ready/Write

.

614159 ,VRODWH

When ISO is ON, the programmable switches on the module and the fader are effec-
tively disconnected from the computer system. The module cannot send commands
to the computer or receive commands from the computer. The module and fader
responds as though it was a non/automated sub-system.

All modules may be put in isolate mode by pressing ALL FADER ISOLATE “SET”
switch on the CCM. Similarly, all modules may be taken out of isolate mode by press-
ing the ALL FADER ISOLATE “CLEAR” switch on the CCM.

61415: 3)/

This electronically latching, logic controlled PFL button allows post EQ, post-insert
monitoring under the control of the osc/comms/monitor module.

61415; +H[DGHFLPDO#GLVSOD\

A seven segment display shows which DC Group Master the channel is currently
selected to.

61415< 0XWH

A Mute switch is included on each channel to allow the operator to instantaneously
switch off the audio signal without disturbing the ‘fader balance’.

The MUTE switch also has a secondary function when used in conjunction with the
CHECK switch, (located on the OSC/PFL module). If a channel is muted (MUTE
switch ON) and the CHECK switch is pressed, the muted channel is unmuted, but all
other channels are forced into MUTE. This allows the originally muted channels to
have a ‘SOLO’ function.

614163 /('#EDUJUDSK#PHWHU

This 20-segment LED meter continuously monitors channel level post EQ and
INSERT point.

614164 )DGHU

A 100mm Penny & Giles conductive plastic fader controls the signal level through the
channel via a VCA circuit on the main audio sub board.

614165 )DGHU#RSHQ

The Fader Open LED (situated below the 20 segment LED meter) illuminated as
soon as the fader moves away from INFINITY, unless the following conditions apply:

The fader has its local VCA MUTE set ON.

The fader is being controlled by a DC Master fader set fully OFF.

The fader is being controlled by a DC Master fader with its local MUTE set ON.

Flash

WRITE

As soon as the fader knob is touched, dynamic data
is sent to the PC. The fader will not respond to data
sent from the PC until the fader knob is released.

READY LED

Mode

System response

Advertising