Cadac F-Type User Manual

Page 42

Advertising
background image

2-14

Central Control Module 7896

F-Type

Revision F2005-2

If there is a fault, a fault code is displayed indicating the type of fault.

This test automatically returns to “Test comms?”.

K,

6KRZ#7LPH

In the system menu, select “

Test Routines?” using the Up or Down arrow button.

The display shows “

Test Routines?”.

Press [

], followed by the Down Arrow button, until the display shows “

Show

Time?”

Press [

]. The display shows the time as set in the PC.

Press [Esc] to return to the system menu or Down arrow to perform next test.

L,

6KRZ#'DWH

In the system menu, select “

Test Routines?” using the Up or Down arrow button.

The display shows “

Test Routines?”.

Press [

], followed by the Down Arrow button, until the display shows “

Show

Date?”

Press [

]. The display shows the date as set in the PC.

Press [Esc] to return to the system menu or Down arrow to perform next test.

NOTE: The Time/Date do not increment when power is removed from the console.
They rely upon SAM updating them when communications are first established.

M,

9LHZ#(UURU#/RJ

In the system menu, select “

Test Routines?” using the Up or Down arrow button.

The display shows “

Test Routines?”.

Press [

], followed by the Down Arrow button, until the display shows “

View Error

Log?”

Press [

]. The display lists the time and date of errors/events.

Select

Time/Date with the arrow keys.

Press the Right arrow key to display the type of error.

Press the Left arrow key to get back to the list of time/date.

NOTE:

Some messages are included in the error log for debugging purposes that

are not in themselves errors. Examples are Time/Date reset or Host is Séance on
the display are not errors.

Press [Esc] to return to the system menu.

N,

&OHDU#(UURU#/RJ

In the system menu, select “

Test System?” using the Up or Down arrow button.

The display shows “

Test System?”.

Press [

], followed by the Down Arrow button, until the display shows “

Clear

Error Log?”

Press [

↵↵

]. The log is cleared and the event is entered in the Error log.

This test automatically returns to the system menu.

Advertising