CHAPTER 6 SENSOR SETTINGS

˽

Source – In normal use, the source is always the radar antenna. However, in some

cases, other sources may be used for demonstrations or evaluations. When the source

is switched to Diagnostic, the antenna is no longer used. Instead, a predetermined

sequence of traffic will appear.

Advanced Tab

The Advanced tab contains higher-level features that will not typically need to be adjusted

by normal users (see Figure 6.3).

Figure 6.3 – Advanced Tab

˽

Wash-out time – Used to set the amount of time a tracker has to be detected before it

is washed out into the background. Range of valid values: 4-60 minutes.

˽

Use Weather Optimizations – This setting will only need to be used if you are install-

ing a sensor in an area with heavy rain or snow. Consult Wavetronix Technical Services

before using this setting.

˽

Blind Sensor Triggers Failsafe – This checkbox will activate after checking the Use

Weather Optimization checkbox and should only be used if the sensor is being in-

stalled in an area with extreme winter weather conditions. Consult Wavetronix Techni-

cal Services before changing this setting.

˽

Queue Forming – This setting is used to fill in the gaps between the cars in a queue. We

recommend that this setting remains checked. Consult Wavetronix Technical Services

before changing this setting.

˽

Presence Update Time – This setting allows you to control how often the sensor push-

es data. Consult Wavetronix Technical Services before changing this setting.