CHAPTER 7 • LANES & STOP BARS

73

Figure 7.9 – Restart or Reboot Window

Note

After you have mounted and aligned the sensor, you should always reboot the sensor
so that thresholds can adjust to the current view.

Editing Thresholds

Warning

Changing Matrix thresholds can have an adverse effect on Matrix performance when
done incorrectly. It is recommended only to edit the Matrix thresholds under the di-
rection of Wavetronix Technical Support.

1 Click on the Edit Thresholds button. This will turn the sensor’s view white and allow

you to change the sensitivity of certain areas in the view.

2 Click anywhere within the sensor’s view and the Sensitivity window will appear (see

Figure 7.10).

Figure 7.10 – Sensitivity Window

The Sensitivity window contains the following options:

˽

Adjust All – Allows you to edit all of the sensor thresholds.

˽

Adjust Region – Allows you to adjust thresholds in a selected region of the sensor view.

˽

Zoom In – Allows you to zoom in and change thresholds of selected areas in the sensor

view (see Figure 7.11).

˽

Reset Region – Allows you to reset only a selected region of thresholds to default settings.

˽

Reset All – Allows you to reset all the sensor thresholds to default settings.