Channel indicators – Wavetronix SmartSensor Matrix (SS-225) - User Guide User Manual

Page 91

Advertising
background image

90

CHAPTER 9 VERIFICATION

Vehicle detections in a stopped queue are represented by a stationary light blue rectangle.

Channel Indicators

When detections enter a zone, they will cause the indicators for the channel mapped to that

zone to turn red. To see the zones mapped to a particular channel, select that channel by

clicking on its indicator (see Figure 9.2). Active zones for the selected channel will be red;

inactive zones for the selected channel will be gray. The channel type will be indicated by

the letter under the channel number (C = Counting, N = Normal, P = Pulse). An “I” will

also be added if the channel is inverted. Click on the yellow button on either side of the

channel indicators to see channels 9–16.

Figure 9.2 – Channel Verification

Note

Only the zones for selected channels will appear. If zones are not mapped to any
channel, they will not be seen in the Verification window.

To see the delay/extend, logic and detector input/phase settings for a single zone, click and

hold on a channel indicator and the following window will appear (see Figure 9.3).

Advertising