5 part names and functions, Reference pulse setting (pulse), 5 par – Yaskawa Junma Series SERVOPACK User Manual

Page 14: Refe, Pulse, English, 5 part names and functions e-13

Advertising
background image

1.5 Part Names and Functions

E-13

English

1.5 Part Names and Functions

„

Reference Pulse Setting (PULSE)

Note: 1. Make settings after turning OFF the power.

2. The factory setting is 0.

Type

Rotary switch for reference
filter setting (FIL)

Rotary switch for reference
pulse setting (PULSE)

Power supply indicator
(PWR)

Connector for power supply /
regenerative unit (CNA)

Connector for motor main
circuit cable (CNB)

Encoder connector (CN2)

Ground terminal

I/O signal connector (CN1)

Alarm indicators (AL1 to AL3)

Reference indicator (REF)

Input voltage

200V

YASKAWA

SJDE- 04 APA-OY

FIL

PULSE

REF

AL1
AL2
AL3

C
N

2

PWR

L1

L2

+

CNA CNB

U

V

W

-

Connector for
communication unit (CN52)

C
N

1

9

F

A

E

B D

C

45

6

7

0

1

8

23

9

F

A

E

B D

C

45

6

7

0

1

8

23

PULSE

C

0

8

9

A

B DE

F

45

3

2

6

7

1

Set

Value

Reference Pulse

Connection Method

Reference

Pulse Type

Input

Frequency

Open collector

or line driver

Line driver

Open collector

or line driver

Line driver

Open collector

or line driver

Line driver

Open collector

or line driver

Line driver

CW + CCW
Positive logic

CW + CCW
Negative logic

Mark + pulse sequence,
Positive logic

Mark + pulse sequence,
Negative logic

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

to 187.5 kpps

187.5 to

750 kpps

to 187.5 kpps

187.5 to

750 kpps

to 187.5 kpps

187.5 to

750 kpps

to 187.5 kpps

187.5 to

750 kpps

Reference

Pulse

Resolution

(P/REV)

1000

2500

5000

10000

1000

2500

5000

10000

1000

2500

5000

10000

1000

2500

5000

10000

PULS

SIGN

CW

CCW

CW

CCW

PULS

SIGN

Advertising
This manual is related to the following products: