Wire size, Caution – Yaskawa Junma Series SERVOPACK User Manual

Page 31

Advertising
background image

3.8 Wiring the Power Supply/Regenerative Unit Connector (CNA)

E-30

3.8 Wiring the Power Supply/Regenerative Unit Connector (CNA)

Use the following procedure when connecting the SERVOPACK to the power supply/regenerative unit connector.

1. Remove the connector from the SERVOPACK.

Make sure to remove the connector from the SERVOPACK when wiring.

2. Strip the outer coating.

Straighten the wire core with your fingers to prevent the wires from unwinding.

3. Open the wire terminal on the power supply connector housing (plug) with the tool (lever for wiring)

using the procedure shown in Fig. A or B.

• Insert the connection hook end of the provided tool into the slot as shown in Fig. A.

Tool must be purchased by the customer.

• Use a standard flat-blade screwdriver (blade width of 2.5 to 3.0 mm (0.09 to 0.12 in)). Put the blade into the

slot, as shown in Fig. B, and press down firmly to open the wire terminal.

Either the procedure shown in Fig. A or B can be used to open the wire insert opening.

4. Insert the wire core into the opening and then close the opening by releasing the tool hook or remov-

ing the screwdriver.

„

Wire Size

• Observe the following precautions when wiring connectors for power supply/regenerative unit and

for motor main circuit cable.

• Remove the connectors from the SERVOPACK prior to wiring.
• Insert only one wire per terminal on the connectors.
• Make sure that the core wire is not electrically shorted to adjacent core wires.

Item

Wire Size

Conductor

Size

Braided wire

AWG14 to AWG22

Single wire

φ1.6mm to φ0.65mm

Sheath Dimension

φ3.8mm to φ1.7mm

CAUTION

9 to 10 mm

fig A

fig B

Tool Type: J-FAT-OT
(JST. Mfg Co., Ltd)

Advertising
This manual is related to the following products: