3.1 Precautions on Wiring

E-19

English

„

Other Precautions

• Make sure that the emergency-stop circuit turns OFF the /S-ON signal as well as the power supply of the main

circuit. Refer to 3.14 EMG Sequence.

• An overtravel function is not provided for the SERVOPACK.

For system safety, include a sequence so that the /S-ON signal will turn OFF when the limit switch is activated.

• If the servomotor is used to drive a vertical axis, install a safety device with an alarm function to prevent the

workpiece from falling down. Failure to observe this precaution may result in injury or damage to the equipment
from fallen workpieces.

• Install an interlock system in the circuit to avoid any accident when opening or closing the machine’s protective

cover.

• Whether the electricity is served or not to the motor, do not use the motor being rotated from the outside.
• When restarting the power supply soon after turning OFF, alarm may occur to the SERVOPACK. Refer to the

power supply holding time in the following table to restart the power supply correctly.

„

Power Loss

Note: Valued obtained with the servomotor with the rated output.

SERVOPACK

Min. Waiting Time

before Restarting

(s)

Model

Capacity

SJDE-01APA-OY

100W

20

SJDE-02APA-OY

200W

SJDE-04APA-OY

400W

SJDE-08APA-OY

750W

30

Power Loss with SERVOPACK Rated Output

Main

Circuit
Power

Supply

Max. Applica-

ble Servomotor

Capacity

kW

SERVOPACK

Model No.

Output

Current

(Effective

Value)

A

Main

Circuit
Power

Loss

W

Diode

Power

Loss

W

IPM

Power

Loss

W

Control

Circuit
Power

Loss

W

Total

Power

Loss

W

Single-

phase

200 V

0.1

SJDE-01APA-OY

0.84

6

0.9

4.2

9

15

0.2

SJDE-02APA-OY

1.1

8

1.8

5.8

17

0.4

SJDE-04APA-OY

2.0

16

3.6

11.9

25

0.75

SJDE-08APA-OY

3.7

27

6.4

20.3

36