Origin search (fn003), Origin, Caution – Yaskawa Junma Series SERVOPACK User Manual

Page 61

Advertising
background image

5.8 Utility Functions

E-60

„

Origin Search (Fn003)

The origin search is designed to position the origin pulse position of the incremental encoder (phase C) and to clamp
at the position.

This function is used when the motor shaft needs to be aligned to the machine.
Motor speed at the time of execution: 60 min

-1

Preparation

The following conditions must be met to perform the origin search.

• All alarms must be cleared.
• The servo ON signal (/S-ON) must be OFF.

Operation Procedure

Use the following procedure. The following operation example shows when the servomotor rotates
counterclockwise until the servomotor stops at the detected phase-C position.

• Perform origin searches without connecting the coupling.

Step

Display after Operation

Keys

Operation

1

Press the

Key to open the Utility

Function Mode main menu, and select

Fn003 using the

or

Key.

2

Press the

Key.

The display is switched to the execution
display of Fn003 (Origin Search Mode).

CAUTION

For aligning the motor
shaft to the machine

Servomotor

Machine

B B

− F U N C T I O N −

F n 0 0 2

F n 0 0 3

F n 0 0 6

F n 0 1 0

U n 0 0 0 =

0

0 0 0 0 0

U n 0 0 2 =

0

0 0 0 0 0

U n 0 0 3 =

0

0 0 0 0 0 0 0 7 7 4

U n 0 0 D =

0

0 0 0 0 0 0 0 0 0 0

B B − Z − S e a r c h −

Advertising