3.14 EMG Sequence

E-39

English

3.14 EMG Sequence

• Use the power ON/OFF signals or the servo ON/OFF signals only when necessary to turn the

servomotor’s power supply ON or OFF.
Failure to observe this caution may result in unpredictable performance of the servomotor.

* A 100 VAC power supply can be used with a SERVOPACK version 03404 or firmware version 0004 or later.

• Make sure that the emergency-stop circuit turns OFF the Servo ON signal and the power supply of

the main circuit when the EMG (emergency stop) signal turns ON.

Because of residual voltage, the servomotor rotates for a few seconds after the power supply has turned
OFF. This may result in injury or damage to the equipment. Make sure that the EMG means the stop of the
motor rotation.

WARNING

NOTE

SERVOPACK

Servo ON

1

2

CNA

CN1

/S-ON

+24VIN

MC1

DC24V

MC1

Noise filter

MC1

MC1

SA

Power

ON

Power

OFF

Power supply
Single-phase 200VAC to 230VAC, Single-phase 100VAC to 115V*
50/60Hz

EMG

L1

L2