4 electronic gear, When the electronic gear is not used, When the electronic gear is used – Yaskawa Junma Series SERVOPACK User Manual

Page 48

Advertising
background image

5.4 Electronic Gear

E-47

English

5.4 Electronic Gear

The electronic gear enables the workpiece travel distance per reference pulse input from the host controller. The
minimum unit of the position data moving a load is called a reference unit.

When the Electronic Gear is Not Used:

Calculate the revolutions.
1 revolution is 6 mm. Therefore, 10 ÷ 6 = 1.6666 revolutions.

Calculate the required reference pulses.
65536 pulses is 1 revolution. Therefore, 1.6666 × 65536 = 109222 pulses.

Input 109222 pulses as reference pulses.

Reference pulses must be calculated per reference.

complicated

When the Electronic Gear is Used:

The reference unit is 1

μm. Therefore, to move the workpiece 10 mm (10000 μm),

1 pulse = 1

μm, so 10000 ÷ 1 = 10000 pulses.

Input 10000 pulses as reference pulses.

Calculation of reference pulses per reference is not required.

simplified

Ball screw pitch: 6 mm

Encoder resolution (16 bit) 65536

1

2

3

The section indicates the difference between using and not using an electronic gear when a workpiece is
moved 10 mm in the following configuration.

Advertising