5.5 Positioning Completed Signal

E-50

„

Related Parameter

* This parameter is only used to set the reference pulse resolution. Use the rotary switch for the reference pulse setting

(PULSE) to set the type of reference pulse. For details, refer to

„

Reference Pulse Setting (PULSE) under 1.5 Part Names

and Functions.

5.5 Positioning Completed Signal

This signal indicates that servomotor movement has been completed during position control.

When the difference between the number of reference pulses output by the host controller and the travel distance of
the servomotor (position error) drops below the set value in the parameter, the positioning completion signal will be
output.

Use this signal to check the completion of positioning from the host controller.

Parameter

No.

Name

Setting Range

Units

Factory

Setting

When

Enabled

Pn21B

Electronic Gear Function
Select Switch

0000 to 0001

0000

After restart

Type

Signal

Name

Connector

Pin Number

Setting

Meaning

Output

/COIN

CN1-14

ON (close)

Positioning has been completed.

OFF (open)

Positioning is not completed.

Electronic Gear Ratio Selection

0

Reference pulse resolution that is in accordance with
the setting of the rotary switch for the reference pulse
setting (PULSE).

1

Reference pulse resolution that is in accordance with
the electronic gear ratio (Pn20E/Pn210).*

Reserved. (Do not change.)

Reserved. (Do not change.)

Reserved. (Do not change.)

4th

3rd 2nd 1st

digit digit digit digit

n. † † † †