2 system configuration, Caution, Warning – Yaskawa Junma Series SERVOPACK User Manual

Page 24: English, 2 system configuration e-23, Sjde servopack sjme servomotors

Advertising
background image

3.2 System Configuration

E-23

English

3.2 System Configuration

* 1. A 100 VAC power supply can be used with a SERVOPACK version 03404 or firmware version 0004 or later.
* 2. A digital operator or JunmaWin can be used with a SERVOPACK version 03303 or firmware version 0003 or later.
* 3. Prepare a 24-VDC power supply for the brake separately from the sequence power supply.

Connectors for motor
main circuit cable (CNB)

Connectors for power
supply/regenerative unit
(CNA)

To the control
circuits of
magnetic
contactor

Encoder cable (for relay)

Motor main circuit cable
(for relay)

I/O signal cable

Host controller

SJDE
SERVOPACK

SJME
Servomotors

L1 L2

REF

Brake relay

24-VDC
power
supply

*

3

Used for a
servomotor
with a brake.

Used for a
regenerative unit.

C

0

8

9

AB

DE

F

45

3

2

6

7

1

C

0

8

9

AB

DE

F

45

3

2

6

7

1

Noise filter
Used to eliminate suppress noise
from power lines for CE marking
requirements.

Molded-case circuit breaker
To protect the equipment and wiring,
always connect a molded-case circuit
breaker.

Magnetic contactor
Used to turn OFF the servo
power supply when using a
regenerative unit or in case
of emergency.

Power supply
Single-phase 100 VAC*

1

Single-phase 200 VAC

Regenerative unit
Used if regenerative
energy is high.

AC reactor
Used for a power
supply harmonic
suppression.

Fuse
To protect the
equipment, always
install fuses.

Surge absorber
(for lightning
surge)

When not using a digital operator or
JunmaWin, never open the protective
cover for the connector.
If the connector is used, a
SERVOPACK failure may result.

CAUTION

Correctly connect the
connectors CNA and CNB.
Incorrect wiring may
result in electric shock,
injury, or damage to
the equipment.
After wiring, install the
connectors as explained
in 3.8 Wiring the Power

Supply/Regenerative

Unit Connector (CNA)
and 3.9 Wiring the

Servomotor Main Circuit

Cable Connector (CNB).

WARNING

Varistor

APA-OY

Communication unit

VCMP

SVON

C O I N

TGON

REF

CHARGE

ALARM

DATA

JOG

SVON

SCROLL

MODE/SET

RESET

SERVO

READ

WRITE

SERVO

YASKAWA

DIGITAL OPERATOR JUSP-OP05A-1-E

PC running
JunmaWin

Digital operator

When using a digital operator, or JunmaWin*

2

Advertising
This manual is related to the following products: