4 trial operation, E-42, Screwdriver – Yaskawa Junma Series SERVOPACK User Manual

Page 43

Advertising
background image

E-42

4 Trial Operation

Failures caused by incorrect wiring or wrong voltage application in the brake circuit may damage
the equipment or cause an accident resulting in death or injury.
Follow the procedures and instructions for wiring and trial operation precisely as described in this
manual.

Use the following procedure to perform trial operation.

Step

Details

1. Installation

• Install the SERVOPACK and servomotor under the installation condi-

tions.
Do not connect the servomotor shaft to the machine.

2. Wiring and PULSE Settings

• Wire the power supply connector, servomotor main circuit cable,

encoder cable, and the I/O signal cable correctly following the pro-
cedures in 3 Wiring.

• If a servomotor with a brake is used, connect all signal cables

including those for the brake power supply and the relay.

• Use the PULSE rotary switch to select the type of controller’s out-

put pulse and set the resolution of the servomotor.
Note: Use the screwdriver to change the setting

on the rotary switch. Never use the
screwdriver for any purpose other than
setting the rotary switch.

3. LED Check

• Turn ON the power and confirm that the REF indicator is lit orange

or green. If the indicator is orange, turn ON the servo ON (S-ON)
input signal and check that the color of the REF indicator changes
from orange to green.

• If the REF indicator is not orange or green, or the indicator of the

AL1, AL2 or AL3 alarm is red, refer to 6 Troubleshooting and clear
the alarm.

4. PULSE Reference Input 1

• Input the reference pulse from the controller, and then check on

the number of the pulses and servomotor’s rotational direction.
Make sure the servomotor rotates in the correct direction while the
REF indicator is blinking green.

• If the servomotor does not rotate according to the reference, refer

to 6 Troubleshooting and clear the alarm.

NOTE

Select the
PULSE setting
with the rotary
switch.

Screwdriver

APA-OY

200V

YASKAWA

SJDE- 04 APA-OY

FIL

PULSE

REF

AL1
AL2
AL3

C

0

8

9

A

B DE

F

45

3

2

6

7

1

C

0

8

9

A

B DE

F

45

3

2

6

7

1

Check that the
color of the REF
indicator changes
to orange or green.

Controller

Reference pulse

APA-OY

Advertising