6 internal torque limit, Related parameters, 6 int – Yaskawa Junma Series SERVOPACK User Manual

Page 53

Advertising
background image

5.6 Internal Torque Limit

E-52

5.6 Internal Torque Limit

This function always limits maximum output torque by setting values of following parameters.

„

Related Parameters

The setting unit is a percentage of the rated torque.

Note: 1. The maximum torque of the servomotor is used when the set value exceeds the maximum torque.

2. If the settings of Pn402 and Pn403 are too low, the torque may be insufficient for acceleration or deceleration of

the servomotor.

Torque waveform

Pn402

Forward Torque Limit

Setting Range

Setting Unit

Factory Setting

When Enabled

0 to 800

1%

800

Immediately

Pn403

Reverse Torque Limit

Setting Range

Setting Unit

Factory Setting

When Enabled

0 to 800

1%

800

Immediately

V

Pn403

Pn402

V

Speed

Maximum torque

Speed

Limiting torque

No Internal Torque Limit

(Maximum Torque Can Be Output)

Internal Torque Limit

Advertising
This manual is related to the following products: