3.1 Precautions on Wiring

E-21

English

„

Noise Prevention

Example of Wiring for Noise Prevention

* 1. A 100 VAC power supply can be used with a SERVOPACK version 03404 or firmware version 0004 or later.
* 2. For the wires connected to the casings for installation purposes, use wires with a diameter of 3.5 mm

2

or larger.

Flat braided copper wires are recommended.

* 3. Use twisted pair wires for section P.

Correct Grounding

• Servomotor frame grounding:

Be sure to connect the FG grounding terminal on the frame of the servomotor to the grounding terminal on the
SERVOPACK.

• Be sure to ground the grounding terminal of the SERVOPACK.
• If the wires of the servomotor’s main circuit are laid in a metal conduit, ground the conduit and the grounding

box.

One-point grounding must be used.

M

(FG)

U

W

V

L2

L1

CN2

CN1

SERVOPACK

SJDE

Servomotor

Operation relay sequence

P

P

P

1LF

AVR

(Ground
-ing)

*3

Casing

Casing

Casing

*2

*2

Casing

Grounding plate

Groudning: Ground to one point only.
Min. grounding resistance: 100

Ω

2LF

Min. wire size
: 3.5 mm

2

Min. wire size
: 3.5 mm

2

Min. wire size
: 3.5 mm

2

Min. wire size: 3.5 mm

2

Min. wire size: 3.5 mm

2

2 mm

2

or larger

Casing

PG

Noise filter

*2

User signal generating circuit

100 VAC

*1

200 VAC