3.12 Connection Examples of Input Signal

E-37

English

3.12 Connection Examples of Input Signal

„

Line Driver Output

Applicable line driver: SN75174 or MC3487 (Manufactured by Texas Instruments or equivalent)

„

Open-collector Output

Set the current limit resistors R1 through R3 so that the input current (i) will be within the following range.
Input Current (i) = 7 mA to 15 mA

SERVOPACK

Photocoupler

Host Controller

1

2

9

8

4

3

/PULS

SIGN

/SIGN

CLR

/CLR

PULS

75

Ω

7mA

∗ޓޓ Twisted-pair wires

CN1

75

Ω

75

Ω

75

Ω

75

Ω

75

Ω

5

6

3.4k

Ω

/S-ON

+24VIN

0V

24VDC Power Supply

+24V

Photocoupler

1

2

9

8

4

3

/PULS

SIGN

/SIGN

CLR

/CLR

PULS

Vcc

R1

i

R2

Tr1

Tr2

Tr3

R3

i

i

75

Ω

75

Ω

75

Ω

75

Ω

75

Ω

75

Ω

SERVOPACK

Photocoupler

7mA

CN1

5

6

3.4k

Ω

/S-ON

+24VIN

0V

+24V

Examples:

When Vcc is +12V: R1 through R3=1 k

Ω

When Vcc is +24V: R1 through R3=2.2 k

Ω

When Vcc is +5V: R1 through R3=180

Ω

Note: The following signal logic applies for an
open-collector output.

Tr1 to Tr3 ON

Equivalent to high level input.

Equivalent to low level input.

Tr1 to Tr3 OFF

Host Controller