5.8 Utility Functions

E-56

Operating Procedure

Use the following procedure.

Note: 1. If the same alarm occurs after more than one hour, the alarm will be saved. If it occurs in less than one hour, it will

not be saved.

2. The display "†.---" means no alarm occurs.
3. Delete the alarm history using the parameter Fn006. The alarm history is not cleared on alarm reset or when the

SERVOPACK main circuit power is turned OFF.

4. CPF00 and CPF01 are the alarms related to digital operator, and not recorded in Alarm Data.
5. Warnings are not recorded in Alarm Data.

Step

Display after Operation

Keys

Operation

1

Press the

Key to open the Utility

Function Mode main menu, and select

Fn000 using the

or

Key.

2

Press the

Key.

The display is switched to the display of
Fn000 (alarm history display).

3

or

Press the

or

Key to scroll

the alarm history display.

4

Press the

Key.

The display returns to the Utility Function
Mode main menu.

B B

− F U N C T I O N −

F n 0 1 2

F n 0 0 0

F n 0 0 2

F n 0 0 3

− A L A R M −

0 : D 0 0 0 0 0 1 2 0 7 1 9 6

1 : 7 2 0 0 0 0 0 0 3 2 6 5 1

2 : 5 1 1

0 0 0 0 0 0 9 0 4 3

3 :

− − −

B B

− A L A R M −

1 : 7 2 0 0 0 0 0 0 3 2 6 5 1

2 : 5 1 1

0 0 0 0 0 0 9 0 4 3

3 :

− − −

4 :

− − −

Time stamps

Alarm Number

Alarm Sequence Number
The higher the number,
the older the alarm data.

B B

B B

− F U N C T I O N −

F n 0 1 2

F n 0 0 0

F n 0 0 2

F n 0 0 3