Troubleshoot ih browser error messages, Troubleshoot missing radios, E 34) – ProSoft Technology RLXIB-IHA-A User Manual

Page 34

Advertising
background image

Diagnostics and Troubleshooting

RLXIB-IHA ♦ 802.11a

User Manual

RadioLinx® 802.11a Industrial Hotspot

Page 34 of 123

ProSoft Technology, Inc.

July 25, 2013

3.5

Troubleshoot IH Browser error messages

One error message commonly occurs when you use the IH Browser, "Unable to
scan for AP's". You can easily remedy this error.

This error occurs when the IH Browser attempts to scan for radios and no valid
network connection exists on the PC, wired or wireless.

To correct this error, Confirm that your PC has at least one active network (LAN)
connection; it could be a wired Ethernet connection or a wireless 802.11
connection. One way to determine if your network connections are active is to
look in the system tray in the lower-right corner of your desktop. The two-PC icon
indicates a connection and the icon with a red X indicates an inactive connection.
If no connections are visible in the system tray, check Network Connections in
the Control Panel.

Confirm that the network connection has a valid IP address. Your network
connection might need to have a static IP address assigned to it. Check the IP
address of your network connection to determine that one has been assigned.

3.6

Troubleshoot missing radios

If radios are not visible in the IH Browser, try the following:
 First, click the S

CAN

button again. Scans are sent as broadcast messages,

which can be dropped in RF connections, requiring the user to scan again.

 Second, disable any software firewall running on your PC (This is most

common in Windows XP and newer). Open the N

ETWORK CONNECTIONS

folder in your Windows Control Panel, then open the L

OCAL

A

REA

C

ONNECTION

P

ROPERTIES

window and verify that the check box under

I

NTERNET

C

ONNECTION

F

IREWALL

is not checked.

 If the preceding approaches do not help, the PC running the IH Browser and

the radios are probably not connected to the same local network. Verify your
connections.

 If you are in topological view, any unlinked radios may be at the bottom of the

window. Scroll down to see all radios. If you still cannot see radios with the IH
Browser, call technical support.

Advertising