Enter/Exit Programming Mode

Interleaved 2 of 5 (I 2 of 5)

134

QuickScan™ I QD24XX/QBT24XX/QM24XX

I 2 of 5 Set Length 1

This feature specifies one of the bar code lengths for

I 2 of 5 Length Control on page 133

.

Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in

Fixed Length Mode. The length includes the bar code’s check and data characters. The length

can be set from 2 to 50 characters in increments of two.

Table 7

provides some examples for setting Length 1. See

page 251

for detailed instructions on

setting this feature.

Table 7. I 2 of 5 Length 1 Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

2 Characters

6 Characters

14 Characters

50 Characters

2

Pad with leading zeroes to
yield two digits

02

06

14

50

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT I 2 of 5 LENGTH 1 SETTING

5

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘2’

‘0’ and ‘6’

‘1’ and ‘4’

‘5’ AND ‘0’

6

Scan ENTER/EXIT PROGRAMMING MODE

$CI2L1

Select I 2 of 5 Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.

~

CANCEL

DEFAULT

06 = Length 1 is 6 Characters