1D Symbologies

Enter/Exit Programming Mode

Product Reference Guide

175

MSI Set Length 2

This feature specifies one of the bar code lengths for

MSI Length Control on page 173

. Length 2

is the maximum label length if in

Variable Length on page 251

Mode, or the second fixed

length if in

Fixed Length on page 251

Mode. Length includes the bar code’s check, data, and

full-ASCII shift characters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length

(only one fixed length).

Table 22

provides examples for setting Length 2. See

page 251

for detailed instructions on set-

ting this feature.

Table 22. MSI Length 2 Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

00 (Ignore This

Length)

07 Characters

15 Characters

50 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT MSI LENGTH 2 SETTING

4

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘0’

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

5

Scan ENTER/EXIT PROGRAMMING MODE

$CMSL2

Select MSI Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save
the entry string. You can then start again at the beginning.

~

CANCEL

DEFAULT

50 = Length 2 is 50 Characters

Advertising