Wedge Quiet Interval

Specifies amount of time to look for keyboard activity before scanner breaks keyboard connec-

tion in order to transmit data to host. The selectable range for this setting is 00 to 990 millisec-

onds (00-0x63 by 01) in increments of ten milliseconds.

See

page 248

in “References” for

detailed information and examples for setting this feature.

$CKBQI

Set Wedge Quiet Interval

To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
left followed by the digits from the Alphanumeric char-
acters in

Appendix D, Keypad

representing your

desired character(s). End by scanning the ENTER/EXIT
bar code again.

Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.

~

CANCEL

DEFAULT

0A = Quiet Interval is 100 milliseconds

Intercode Delay

Specifies the delay between labels transmitted to the host for this interface. The selectable

range for this feature is from 0 to 99 seconds.
See

page 250

in “References” for detailed information and examples for setting this feature.

$CKBID

Set Intercode Delay

To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
left followed by the digits from the Alphanumeric char-
acters in

Appendix D, Keypad

representing your

desired character(s). End by scanning the ENTER/EXIT
bar code again.

Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.

~

CANCEL

DEFAULT

00 = No Wedge Intercode Delay