Industrial 2 of 5 set length 1, Default – Datalogic QuickScan I QD2400 User Manual

Page 153

Advertising
background image

1D Symbologies

Enter/Exit Programming Mode

Product Reference Guide

143

Industrial 2 of 5 Set Length 1

This feature specifies one of the bar code lengths for

Industrial 2 of 5 Length Control on page

142

. Length 1 is the minimum label length if in

Variable Length on page 115

Mode, or the first

fixed length if in

Fixed Length on page 115

Mode. Length includes the bar code’s data charac-

ters only. The length can be set from 0 to 50 characters.

Table 11

provides some examples for setting Length 1. See

page 251

if you want detailed

instructions on setting this feature.

Table 11. Industrial 2 of 5 Length 1 Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

00 Characters

07 Characters

15 Characters

50 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 1 SETTING

4

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘0’

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

5

Scan ENTER/EXIT PROGRAMMING MODE

$CU2L1

Select Industrial 2 of 5 Set Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and not save
the entry string. You can then start again at the beginning.

~

CANCEL

DEFAULT

01 = Length 1 is 1 Character

Advertising