Scanning Active Time

This setting specifies the amount of time that the reader stays in scan ON state once the state is

entered. The range for this setting is from 1 to 255 seconds in 1-second increments.
Follow these instructions to set this feature:

1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20

= 020, etc.

3. Go to

page 81

and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-

ming Mode.

4. Scan the bar code: SELECT SCANNING ACTIVE TIME SETTING.
5. Scan the appropriate three digits from the keypad in

Appendix D, Keypad

, that represent

the duration which was determined in the steps above. You will hear a two-beep indication

after the last character.

NOTE

If you make a mistake before the last character, scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the beginning.

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.

This completes the procedure. See

Table 39

for some examples of how to set this feature.

Table 39. Scanning Active Time Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

1 Second

90 Sec. (1.5 min.) 180 Sec. (3 min.)

255 Seconds (4.25

min.)

2

Pad leading zero(es)

001

090

180

255

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT SCANNING ACTIVE TIME SETTING

5

Scan Three Characters From

Appendix D, Keypad

‘0’, ‘0’ and ‘1’

‘0’, ‘9’ and ‘0’

‘1’, ‘8’ and ‘0’

‘2’, ‘5’ and ‘5’

6

Scan ENTER/EXIT PROGRAMMING MODE

Advertising