8

QuickScan™ I QD24XX/QBT24XX/QM24XX

Replacing the Battery Pack

NOTE

Before proceeding, read “Battery Safety” on the preceding pages. Datalogic recommends
annual replacement of rechargeable battery packs to ensure maximum performance.

1. Using a coin or a screwdriver, unscrew the bottom of the battery pack until it is disen-

gaged.

The battery pack will rise slightly in the rear, pushed by the contact springs.

2. Extract the battery pack by slightly rotating the pack and pulling away from the reader.

To mount the new battery pack reverse the process:

1. Insert the top of the new pack inside the reader’s handle.
2. Rotate the battery pack downward while pressing the bottom side of the battery pack (to

seat securely into the contacts springs) so that the edges of the pack and the handle board

are aligned, while replacing the screw in the bottom of the handle.