Transmit Labels in Code 39 Format

This feature enable/disables translation to Code 39 before transmitting label data to a USB-

OEM host. Only the symbology identifier is modified for the translation. The data is not con-

verted to Code 39 or verified to be valid for Code 39.

Options are:

IBM Standard Format:

Send labels in standard IBM format.

Mixed IBM Standard and Code 39 Format:

Code 39 Format:

Translate the following symbologies to Code 39:

• USB-OEM: Code128, Code 93, and Codabar

DEFAULT

$CIBC300(CR)

Transmit Labels in Code 39 Format =

IBM Standard Format

$CIBC301(CR)

Transmit Labels in Code 39 Format =

Mixed IBM Standard and Code 39 format

$CIBC302(CR)

Transmit Labels in Code 39 Format =

All Code 39 Format