Stand Mode Illumination Off Time

Specifies the amount of time reader illumination stays off after pulling the trigger when in Stand

Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms to 16 sec-

onds). See

page 263

in “References” for a description of this feature.

$CSNTM

Select Stand Mode Time Setting

To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
left followed by the digits from the Alphanumeric char-
acters in

Appendix D, Keypad

representing your

desired character(s). End by scanning the ENTER/EXIT
bar code again.

DEFAULT

04 = 2 Seconds

Scanning Active Time

This setting specifies the amount of time that the reader stays in scan ON state once the state is

entered. The range for this setting is from 1 to 255 seconds in 1-second increments. See

page 264

in “References” for further description of this feature.

$CSNET03(CR)

Scanning Active Time = 3 seconds

$CSNET05(CR)

Scanning Active Time = 5 seconds

DEFAULT

$CSNET08(CR)

Scanning Active Time = 8 seconds