Msi check character calculation, Msi check character transmission, Default – Datalogic QuickScan I QD2400 User Manual

Page 182

Advertising
background image

Enter/Exit Programming Mode

MSI

172

QuickScan™ I QD24XX/QBT24XX/QM24XX

MSI Check Character Calculation

Enables/Disables calculation and verification of an optional MSI check character.

$CMSCC00(CR)

MSI Check Character Calculation = Disable

$CMSCC01(CR)

MSI Check Character Calculation = Enable Mod10

DEFAULT

$CMSCC02(CR)

MSI Check Character Calculation = Enable Mod11/10

$CMSCC03(CR)

MSI Check Character Calculation = Enable Mod10/10

MSI Check Character Transmission

Enables/disables transmission of an MSI check character.

$CMSCT00(CR)

MSI Check Character Transmission = Disable

$CMSCT01(CR)

MSI Check Character Transmission = Enable

DEFAULT

Advertising