Partial Label Reading Control

Enable/Disable to ignore partial labels to be read within the boundary of the field of view.

IPPL00

Partial Label Reading Control = Disable

IPPL01

Partial Label Reading Control = Enable

Decode Negative Image

Enable/Disable the ability to decode a negative image for all symbologies. When this feature is

enabled, you will be unable to read normally-printed labels or programming labels in this man-

ual. Scan the “Disable” bar code below to return the scanner to its default for this feature. To set

decoding for only 2D codes, go to "

2D Normal/Inverse Symbol Control" on page 183

. For addi-

tional options, see the Aladdin configuration application.

NOTE

CAUTION

$P,CIPVR00,P(CR)

Decode Negative Image = Disable

DEFAULT

$P,CIPVR01,P(CR)

Decode Negative Image = Enable

When this feature is enabled, you will be unable to read other programming labels in this
manual.

Unlike some programming features and options, Decode Negative Image selections require
that you scan only one programming bar code label. DO NOT scan an ENTER/EXIT bar code
prior to scanning a Decode Negative Image bar code.