HIGHLIGHTS OF CHANGES

Effective December, 2003 Rev. 3.0

Page

Summary

Cover

Updated photo, revision number, and date.

P-3 through P-14

Added foreign language versions of ‘Safety Instructions for the Wiring
and Installation of this Apparatus’.

P-22

Revised Figure 1 to include remote electronics versions.

1-1

Revised para. 1-2a to include Local operator Interface (LOI) and Model
375 communicator. All IB references to HART Model 275 changed to
read ‘HART Model 275/375’.

1-2

Revised Figure 1-1 to include Oxymitter 4000 with remote electronics.

1-3

Revised para. 1-2c to include reference to remote electronics version.

1-4

Revised para. 1-2d to include differences between units with LOI versus

membrane keypad and to include new Figure 1-3 and Figure 1-4 views.

1-6

Revised NOTE to include LOI operating temperature data.

1-7

Revised Figure 1-7 to include remote electronics versions.

1-14, 1-15

Revised para. 1-7 Specifications to include LOI data, update electronic
noise data, temperature range data, and certification references.

1-16, 1-17

Revised Table 1-1 Product Matrix to update Communication Options and
Calibration Accessories, and to include Probe-to-Electronics Cables.

2-1

Revised para. 2-1a to reference remote electronics version and LOI.

2-4

Revised Figure 2-3 to indicate the integral electronics version is shown.

2-9

Added para. 2-1c to discuss mounting of remote electronics version.

2-12

Added new para. 2-3 for installing remote electronics version.

3-1

Revised section heading to denote configuration instructions applicable
to membrane keypad version only.

3-2

Revised para. 3-1e.4 to define new voltage selection parameters.

3-3

Revised Figure 3-2 to update default parameter settings.

3-5, 3-6

Revised para. 3-3a to correct mA signal level values. Moved power up
procedure to Section 5.

4-1 through 4-6

Added new Section 4 to discuss unit configuration with the LOI. Previous
Section 4 is now Section 5.

5-1

Revised section heading to apply to membrane keypad version only.

6-1 through 6-6

Added new Section 6 to discuss Operation with the LOI. Previous
Sections 5 through 11 are now Sections 7 through 13.

8-1

Added new Figure 8-1 and related overview discussion.

8-3

Revised para. 8-5 to include reference to LOI error indications.

8-4

Corrected mA signal level values in notes for Table 8-1. Added Table 8-2
to identify to LOI fault/alarm messages.