Saving the data using data out, D-160 owner's manual (saving and loading data), Connecting an external device – Fostex D-160 User Manual

Page 104: D-160, Setting up an external device, Executing the save operation, Optical, Ne pas ouvrir :risque de choc electrique, Do not open risk of electric shock, Digital in

Advertising
background image

D-160 Owner's Manual (Saving and loading data)

104

9

10

11

12

13

14

15

5

6

7

8

16

1

2

3

4

5

6

7

8

1

2

9~16

1~8

9~6

DATA

OUTPUT

INPUT

1~8

OPTICAL

INPUT

OUTPUT

THRU

ANALOG IN

ANALOG OUT

SCSI

MIDI

TO RAIN OR MOISTURE.

SHOCK. DO NOT EXPOSE THIS EQUIPMENT

TO REDUCE THE RISK OF FIRE OR ELECTRIC

WARNING:

NE PAS OUVRIR

:RISQUE DE CHOC ELECTRIQUE

AVIS

DO NOT OPEN

RISK OF ELECTRIC SHOCK

CAUTION

4

3

1. Saving the data using DATA OUT

* Restore the initial settings on the D-160.

* Set the same sampling rate on the external digital device and the D-160.

Connecting an external device

Connect DATA OUTPUT 1-8 connector of the D-160 to the digital input connector on the
external digital device.

<Notes>

* The D-160 has DATA OUT connectors for an S/P DIF digital signal (OPTICAL) and for an adat

digital signal. These connectors have the same shape but carry different information.

* Use the DATA OUTPUT 1-8 connector to save data. Do not use the DATA OUTPUT 9-16

connector.

* At save/load using DAT and adat, independent save/load in 8 track units is possible.

In this case, the data in 8 track units are not distinguished as track 1~8 or 9~16 but simply
handled as eight track data. Therefore, because this 8 track data is compatible with D-90 if it
is in 8 track units (any one combination of 1~8, 9~16 or 17~24), data saved from D-160 can
be loaded in tracks 1~8 of the D-90. In this case, data in the tracks which were not loaded will
remain intact.

D-160

DIGITAL IN

DATA OUTPUT 1-8

External Digital Equipment (DAT or RD-8 or Adat)

• If the external device has only COAXIAL type (RCA) digital I/O connectors, connect an

optional COP-1 (optical/coaxial converter) to use an S/P DIF digital signal.

• Connecting both output and input connectors on the D-160 to the input and output

connectors on the external digital device respectively may generate a digital loop.
Refer to “4-3. Connecting a digital mixer” on page "65" for more information.

Setting up an external device

1. Set the same sampling rate to that of the D-160.

2. Select digital input on the external device so that the external device will accept a digital signal.

On some external devices, you may have to set up so that the external device will synchronize
with the incoming digital signal. For example, if you are using a Fostex RD-8, select “DIGITAL IN”
and set “Clock Source (external sync signal)” to “Word Optical (adat).”

<Note>

If the external device does not accept the digital signal or if you notice digital noise, check
the connection, cabling, and the settings of the D-160 and the external device.

* Refer to the instruction manuals that came with any external digital device for details.

Executing the save operation

Use the “Save PGM?” menu in Setup mode.

* Output format available: adat, DAT, SCSI

* Programs available: P1 - P99

* You can save one Program at a time.

Advertising