Fostex D-160 User Manual

Page 124

Advertising
background image

D-160 Owner's Manual (MIDI sync function)

124

4

. A random offset time is set by the SETUP mode "MTC offset time setting."

# Refer to page "152", SETUP mode "2-10. MTC offset time setting" for operating
procedure and details.

5

. "00" is set with the SETUP mode "MIDI device ID setting."

# Refer to page "161", SETUP mode "2-18. MIDI device ID setting" for operating
procedure and details.

6

. Set to "adat" the digital signal to be output by the SETUP mode "Digital output track setting."

# Refer to page "159", SETUP mode "2-16. Digital output track setting" for operating
procedure and details.

7

. Press the DISP SEL key while pressing the EXECUTE/YES key to change the time base display

to MTC.

Setup of D-160 (#2) (Slave 1) and D-160 (#3) (Slave 2)

1

. Set the SETUP mode "MTC Frame rate setting" to the same frame rate as in D-160 (#1).

* Refer to page "151", SETUP mode "2-9. MTC Frame rate setting" for operating
procedure and details.

2

. Set the SETUP mode "MTC offset mode setting" to the same mode as in D-160 (#1).

# Refer to page "153", SETUP mode "2-11. MTC offset mode setting" for operating
procedure and details.

3

. Set the SETUP mode "MTC offset time setting" to the same offset time as in D-160 (#1).

# Refer to page "152", SETUP mode "2-10. MTC offset time setting" for operating
procedure and details.

4

. Set the SETUP mode "MIDI device ID setting," to "01" in D-160 (#2), and to "02" in D-160 (#3).

# Refer to page "161", SETUP mode "2-18. MIDI device ID setting" for operating
procedure and details.

5

. Using the SETUP mode "Slave mode setting," set slave mode to "On," and the SETUP mode

"Slave mode type setting," the slave type to "adat."

* Slave mode initial setting: Off

* Permissible setup item: On, Off

* Slave type initial setting: SP DIF

* Permissible setup item: Vari, SP DIF, adat, Free

* This item can be set for each program.

* The setting can be saved/loaded as song data.

* This setting will be held even though power is switched OFF.

# Refer to page "154", SETUP mode "2-12. Slave mode setting" , and to page "155",
SETUP mode "2-13. Save mode type setting", for operating procedure and details.

6

. Press the DISP SEL key while pressing the EXECUTE/YES key to change the time base display

to MTC.

<Note>

After this setup, check the following in D-160 (#2) and D-160 (#3).

* Blinking of "CHASE" in the display:

This will change to constant lit upon completing chase lock in later operation.

* "DIGITAL" is lit in the display:

This means it is externally synchronized against the input digital signal.

<Note>

Do not insert or remove the optical cable connected to DATA IN when the slave mode is
set to "On." Doing so could generate noise and affect external equipment.

Advertising