Problem 17 – engine cranksbut won’t start, Troubleshooting flow charts, Problem 17 – engine cranks but won’t start – Generac Power Systems 8 kW LP User Manual

Page 121: Part 4

Advertising
background image

Page 119

sEctioN 4.3

trouBlEsHootiNG floW cHarts

BAD

REPLACE CHOKE

SOLENOID

CLEAN,

REGAP OR

REPLACE

REPLACE CIRCUIT BOARD

REPLACE FUEL SOLENOID

TEST 66 – CHECK

FUEL SUPPLY AND

PRESSURE

REPLACE FUEL

REGULATOR

TEST 70 –

CHECK FOR

IGNITION

SPARK

TEST 69 – CHECK

CHOKE SOLENOID

TEST 74 – CHECK

IGNITION

MAGNETOS

TEST 73 – CHECK

SHUTDOWN WIRE

TEST 77 –

CHECK AND

ADJUST VALVES

TEST 71 –

CHECK SPARK

PLUGS

TEST 72 –

CHECK ENGINE

COMPRESSION

TEST 68 – CHECK

FUEL SOLENOID

TEST 67 – CHECK

CIRCUIT BOARD

WIRE 14 OUTPUT

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

BAD

BAD

BAD

BAD

BAD

BAD

BAD

BAD

BAD

BAD

REPAIR OR REPLACE

ADJUST OR

REPLACE

REPAIR OR

REPLACE SHORTED

WIRE 18 OR CIRCUIT

BOARD

CHECK

FLYWHEEL

KEY

REFER TO ENGINE

SERVICE MANUAL

FIND AND CORRECT

CAUSE OF NO FUEL

OR LOW PRESSURE

READJUST

Problem 17 – Engine Cranks but Won’t Start

CHECK AIR FILTER -

REPLACE AS NEEDED

SINGLE CYLINDER UNITS

V-TWIN UNITS

TEST 16 – CHECK
STEPPER MOTOR

CONTROL

DC CONTROL

Part 4

Advertising
This manual is related to the following products: