Figure 39.

Figure 40.

Figure 41.

17. Rotor Removal: Cut 2.5 inches from the rotor bolt. Slot

the end of the bolt to suit a flat blade screwdriver. Slide

the rotor bolt back through the rotor and use a screw-

driver to screw it into the crankshaft. Use a 3” M12x1.75

bolt to screw into rotor. Apply torque to the 3” M12x1.75

bolt until taper breaks. See Figure 43.

Figure 42.

11. Remove Engine: Using a 13mm socket, remove the two

engine mount nuts with ground wires. See Figure 43.

Figure 43.

Page 161

DISASSEMBLY

sEctioN 6.1

maJor DisassEmBlY

Part 6