Test 71 – check spark plugs – Generac Power Systems 8 kW LP User Manual

Page 138

Advertising
background image

Page 136

Figure 29. Checking Engine Miss

RESULTS:

1. If no spark or very weak spark occurs, go to Test 73.
2. If sparking occurs but engine still won’t start, go to Test 71.
3. When checking for engine miss, if sparking occurs at

regular intervals but engine miss continues, go to Test 20.

4. When checking for engine miss, if a spark miss is readily

apparent, go to Test 74.

teSt 71 – check Spark pluGS

DISCUSSION:
If the engine will not start and Test 70 indicated good
ignition spark, perhaps the spark plug(s) are fouled or
otherwise damaged. Engine miss may also be caused
by defective spark plug(s).

PROCEDURE:

1. Remove spark plugs and clean with a penknife or use a

wire brush and solvent.

2. Replace any spark plug having burned electrodes or

cracked porcelain.

3. Set gap on new or used spark plugs as follows:

Engine size

kW

rating

Plug Gap

recommended

Plug

410 cc

8 kW

0.030 inch

RC14YC

530 cc

10 kW

0.030 inch

BPR6HS

990 cc

10-17 kW 0.040 inch

RC14YC

999 cc

20 kW

0.030 inch

RC12YC

RESULTS:

1. Clean, re-gap or replace spark plugs as necessary.
2. If spark plugs are good, refer back to flow chart.

NORMAL

MISFIRES

PRE-IGNITION

DETONATION

Figure 30. Spark Plug Conditions

Figure 31. Checking Spark Plug Gap

teSt 72 – check enGine / cylinder leak

doWn teSt / compreSSion teSt

GENERAL:
Most engine problems may be classified as one or a
combination of the following:

• Will not start
• Starts hard
• Lack of power
• Runs rough
• Vibration
• Overheating
• High oil consumption

Part 4

DC CONTROL

sEctioN 4.4

DiaGNostic tEsts

Advertising
This manual is related to the following products: