STATOR/ROTOR/ENGINE REMOVAL:

1. Remove Top Exhaust Enclosure Covers: Using a 10mm

socket, remove the nine bolts from the exhaust top cov-

ers. Remove covers. See Figure 23.

Figure 23.

2. Remove Side Exhaust Enclosure Cover: Using a 10mm

socket, remove the five bolts from the exhaust side

cover. Remove side covers. See Figure 24.

Figure 24.

3. Remove Exhaust Flex Cover: Using a 10mm socket,

remove the two bolts from the exhaust flex pipe cover.

Remove the cover. See Figure 25.

Figure 25.

4. Remove Exhaust Flex Pipe: Using a ½” socket remove

the front and rear muffler clamp. Slide exhaust flex

toward engine completely exposing the muffler flange.

See Figure 26.

Figure 26.

5. Remove Muffler and Tail Pipe: Using a ½” socket remove

the muffler clamp and tail pipe. Using a 10mm socket,

remove the four bolts from the muffler mounts and

remove muffler. See Figure 27.

Page 157

DISASSEMBLY

sEctioN 6.1

maJor DisassEmBlY

Part 6

Advertising
This manual is related to the following products: