background image

• An open circuit condition
• A “short-to-ground” condition
• A short circuit between windings

note: the resistance of stator windings is very low.
Some meters will not read such a low resistance,
and will simply indicate continuity. recommended
is a high quality, digital type meter capable of read-
ing very low resistances.

PROCEDURE, 8 kW:

1. Disconnect Stator Leads 11 and 44 from the main circuit

breaker.

2. Disconnect Stator Leads 22 and 33 from the neutral

connection separate the leads.

3. Make sure all of the disconnected leads are isolated

from each other and are not touching the frame during

the test.

4. Set a VOM to measure resistance.
5. Connect one test lead to Stator Lead 11. Connect the

other test lead to Stator Lead 22. Note the resistance

reading and compare to the specifications in the front of

this manual.

6. Connect one test lead to Stator Lead 33. Connect the

other test lead to Stator Lead 44. Note the resistance

reading and compare to the specifications in the front of

this manual.

PROCEDURE, 10 kW:

1. Isolate the generator from the transfer switch by dis-

connecting the load wires from the main breaker inside

the generator.

2. Disconnect Stator Leads 22 and 33 from the neutral

connection and separate the leads.

3. Make sure all of the disconnected leads are isolated

from each other and are not touching the frame during

the test.

4. Turn the Main Breaker to the "ON" or CLOSED position.
5. Set a VOM to measure resistance.
6. See Figure 4 for proper testing points.
Connect one

meter test lead to Wire 11 on the load side of the main

breaker. Connect the other meter test lead to Wire 22

(power winding). Note the resistance reading and com-

pare to the specifications in the front of this manual.

7. Connect one test lead to Stator Lead 44 on the load

side of the main breaker. Connect the other test lead

to Stator Lead 33 (power winding). Note the resistance

reading and compare to the specifications in the front of

this manual.

note: Wire 11 and Wire 44 could be switched on
the main breaker. if an inFinity reading is indi-
cated try putting the meter leads on the other
output terminal of the breaker. if inFinity is still
read then an actual fault may exist.

TEST WINDINGS FOR A SHORT TO GROUND:

7. Make sure all leads are isolated from each other and are

not touching the frame.

8. Connect one test lead to a clean frame ground. Connect

the other test lead to stator lead Wire 11.

a. The meter should read INFINITY.

b. Any reading other than INFINITY indicates a

“short to ground” condition.

9. Repeat Step 7 using stator lead 44

TEST FOR A SHORT CIRCUIT BETWEEN WINDINGS:

10. Connect one test lead to stator lead 11. Connect the

other test lead to stator lead 33.

a. The meter should read INFINITY.

b. Any reading other that INFINITY indicates a

short between windings.

11. Repeat Step 10 using Wire 44.

RESULTS:

1. Stator winding resistance values is a test of winding conti-

nuity and resistance. If a very high resistance or INFINITY

is indicated, the winding is open or partially open.

2. Testing for a “grounded” condition: Any resistance

reading indicated the winding is grounded.

3. Testing for a “shorted” condition: Any resistance reading

indicated the winding is shorted.

4. If stator tests good and wire continuity tests good, refer

back to flow chart.

teSt 9 – check capacitor

DISCUSSION:
The brushless rotor system relies on the charging and
discharging of a capacitor to induce voltage into the
rotor and also to regulate voltage once 240 VAC is
achieved. If the capacitor fails, only residual magnetism
of the rotor will be measured at the Main Breaker.

*

Danger: the capacitor may need to be dis-

charged before testing. a capacitor can be
discharged by crossing the terminals with
a metal insulated screw driver.

*

Danger: use proper protective equipment

when dealing with a capacitor that has
exploded.