Lenovo THINKSERVER RS210 User Manual

Page 106

Advertising
background image

Table 5. DSA Preboot messages (continued)

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

v

See Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained service
technician.

v

Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new
device drivers or to submit a request for information.

Message
number

Component

Test

State

Description

Action

405-903-xxx

BroadCom
Ethernet
Device

Test Internal
Memory

Failed

1.

Make sure that the component firmware is at the
latest level. The installed firmware level is shown
in the DSA event log in the Firmware/VPD
section for this component. For more information,
see “Updating the firmware” on page 212.

2.

Run the test again.

3.

Check the interrupt assignments in the PCI
Hardware section of the DSA event log. If the
Ethernet device is sharing interrupts, if possible,
use the Setup utility see “Using the Setup Utility”
on page 200)
to assign a unique interrupt to the
device.

4.

Replace the component that is causing the error. If
the error is caused by an adapter, replace the
adapter. Check the PCI Information and Network
Settings information in the DSA event log to
determine the physical location of the failing
component.

5.

If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support..

405-904-xxx

BroadCom
Ethernet
Device

Test Interrupt Failed

1.

Make sure that the component firmware is at the
latest level. The installed firmware level is shown
in the DSA event log in the Firmware/VPD
section for this component. For more information,
see “Updating the firmware” on page 212.

2.

Run the test again.

3.

Check the interrupt assignments in the PCI
Hardware section of the DSA event log. If the
Ethernet device is sharing interrupts, if possible,
use the Setup utility see “Using the Setup Utility”
on page 200)
to assign a unique interrupt to the
device.

4.

Replace the component that is causing the error. If
the error is caused by an adapter, replace the
adapter. Check the PCI Information and Network
Settings information in the DSA event log to
determine the physical location of the failing
component.

5.

If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support..

98

ThinkServer ThinkServer RS210, Types 6531, 6532, 6533, and 6534: Hardware Maintenance Manual

Advertising