Lenovo THINKSERVER RS210 User Manual

Page 33

Advertising
background image

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.

v

See Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

v

Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints,
tips, and new device drivers or to submit a request for information.

Error code

Description

Action

2018001

PCI Express uncorrected or uncorrected error 1. Check the riser-card LEDs.

2.

Reseat all affected adapters and riser cards.

3.

Update the PCI adapter firmware.

4.

Remove the adapter from the riser card.

5.

Replace the following components one at a time,
in the order shown, restarting the server each
time:

a.

Riser card

b.

(Trained service technician only) System board

2018002

Option ROM resource allocation failure

Informational message that some devices might not
be initialized.

1.

If possible, rearrange the order of the adapters in
the PCI slots to change the load order of the
optional-device ROM code.

2.

Run the Setup utility, select Startup Options, and
change the boot priority to change the load order
of the optional-device ROM code.

3.

Run the Setup utility and disable some other
resources, if their functions are not being used, to
make more space available.

a.

Select Startup Options → Planar Ethernet
(PXE/DHCP)

to disable the integrated

Ethernet controller ROM.

b.

Select Advanced Functions → PCI Bus Control

PCI ROM Control Execution

to disable the

ROM of the adapter in the PCI slots.

c.

Select Devices and I/O Ports to disable any of
the integrated devices.

4.

Replace the following components one at a time,
in the order shown, restarting the server each
time:

a.

Each adapter

b.

(Trained service technician only) System board

3xx0007 (xx
can be 00 -
19)

Firmware fault detected, system halted

1.

Recover the server firmware to the latest level.

2.

Undo any recent configuration changes, or clear
CMOS memory to restore the settings to the
default values (see Table 6 on page 111).

3.

Remove any recently installed hardware.

Chapter 4. Diagnostics

25