Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.

v

See Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Sensor CPU nOverTemp has
transitioned to non-recoverable.
(n = microprocessor number)

Error

A sensor has changed to
Nonrecoverable state.

1.

Make sure that the fans are
operating, that there are no
obstructions to the airflow,
that the air baffle is in place
and correctly installed, and
that the server cover is
installed and completely
closed.

2.

Make sure that the heat sink
for microprocessor n is
installed correctly.

3.

(Trained service technician
only) Replace microprocessor
n.

(n = microprocessor number)

A bus timeout has occurred on
system %1.
(%1 = CIM_ComputerSystem.
ElementName)

Error

A bus timeout has occurred.

1.

Remove the adapter from the
PCI slot that is indicated by a
lit LED.

2.

Replace the extender card.

3.

Remove all PCI adapters.

4.

(Trained service technicians
only) Replace the system
board.

The System %1 encountered a POST
Error.
(%1 = CIM_ComputerSystem.
ElementName)

Error

A POST error has occurred.
(Sensor = ABR Status)

1.

Recover the server firmware
from the backup page (see
“Recovering the server
firmware” on page 100).

2.

Update the server firmware to
the latest level.
Important:

Some cluster

solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.

34

ThinkServer ThinkServer RS210, Types 6531, 6532, 6533, and 6534: Hardware Maintenance Manual